<LOGO>
FM Transmitter Measurement Report
Created: 2025-12-26 04-52-18
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
92.10 MHz 5/5, 33 dBuV IMPULS
Pilot RDS Phase Difference
0.0 kHz 4.1 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 2,0 kHz
MIN Hold Max. Samples at Total Samples % above 77,0 kHz
13 kHz 44 kHz 18267 0,0328
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-0,5 dBr 0,06 dBr 0,4 dBr 36,9
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" IMPULS " 2203 0 (No PTY) 1 0 1 1 --:--
RT
"RADIO IMPULS - RADOST ZE ZIVOTA "
AF EON
87.6, 89.0, 91.4, 96.6, 99.6, 100.3, 100.9, 102.0, 102.9, 104.3, 106.0 MHz -
FM Scope Max at: 44 kHz MIN: 13 kHz % above 77 kHz: 0,0328 Acquired: 2025/12/26 4:52:15 Total samples: 18267 Equivalent time: 0:15:13 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000
FM Scope MAX: 0,4 dBr MIN: -0,5 dBr AVE: 0,06 dBr % above 0,2 dBr: 36,9 Last value: 0,2 dBr (2025/12/26 4:52:14) 04:38 04:40 04:42 04:44 04:46 04:48 04:50 04:52 -4 -2 0 2 4 Pm [dBr] 0 5 Signal Quality